Technical Data
| Type of discharge: (combinations possible) |
aperiodically damped Sine half wave (optional) Damped oscillation (optional) |
||
| Maximum energy: | 5000 Ws | ||
| Maximum voltage: | 2000 V | ||
| Voltage setting: | Accuracy in the range of 200 V - 2000 V: ± 30 V Accuracy in the range of 30 V - 2000 V ± 0,1 V (optional) |
||
| Maximum current: | approx. 25000 A (depending on fixture connected) | ||
| Cycle time:* | 1 - 6 s (depending on energy and charging capacity) | ||
| High current outputs: | Standard: 1, Optional: 2 | ||
| Internal PLC: | Simatic® PLC S7, Software updates via Micro Memory Card | ||
| Operation: | Instruments (Potentiometer, Analog display, "Start"-key) Fully grafic 5.7" STN-Touch panel (optional) Remote control via interfaces (RS232 C, 20 mA TTY, RS 485, Profibus etc. optional) |
||
| Current monitoring: | Measurement and control of impulse current (optional) | ||
| Supply: | 1-phase: 230 V AC ± 10 %, 50/60 Hz, 16 A 3-phase: 400 V AC ± 10 %, 50/60 Hz, 32 A (other supplies possible) |
||
| Weight: | approx. 200 kg (depending on model type) | ||
| Dimensions - Width: - Height: - Depth: |
710 mm 1100 mm 800 mm |
||
Safety functions
Safety is a key area for Magnet-Physik. Operation without interruption and protection of the operator.All basic functions are controlled continuously by the PLC. The voltage at the capacitor banks are monitored by the PLC and additionally by a separate circuit. In case of a fault or interruption from mains the capacitors are discharged automatically. The magnetizers are equipped with two of these circuits. The PLC also monitors the charging unit and in case of a failure it separates it from the mains and controls the automatic capacitor discharge.
Magnet-Physik fixtures are equipped with thermocouples that allow montitoring of the fixture heat. A second internal switch also will open should excessive heat build up.
One emergency-off switch is on the operating panel of the magnetizer. A second can be connected externally.
For further information contact our sales.